Nova 200 Instrument Type Microscopy Techniques SEM, EDSImmersion Lens Imaging Staff Manager Alireza Ghaffari Staff Email [email protected] Staff Phone 626-395-3984 Reserve time on FBS Request training via FBS User Dashboard Lab Location B203 Steele Lab Phone 626-395-1542 Manufacturer FEI (now Thermo Fisher) Model Nova 200 NanoLab Contents 1 Description 1.1 SEM Applications 1.2 EDS Applications 2 Resources 2.1 Equipment Status 2.2 SOPs & Manuals & SDS 2.3 Video Tutorials 2.4 Graphical Handouts 2.5 Presentations 2.6 Simulation Software 2.7 Calibrate Measurements with NIST Standard 2.8 Sample Preparation 2.9 Stubs for specimen mounting 2.10 Guide to Choosing KNI SEMs & FIBs 3 Specifications 3.1 Manufacturer Specifications 3.2 SEM Specifications Description

The Nova 200 is the KNI's highest-resolution field-emission gun (FEG) analytical scanning electron microscope (SEM), equipped with an immersion lens for imaging sub-10 nm features and energy dispersive spectroscopy (EDS) for compositional analysis. It is also outfitted with a gallium focused ion beam (Ga-FIB) column, which is currently not operational because the Nova 600 NanoLab and ORION NanoFab together meet the KNI's Ga-FIB demand; Ga-FIB could be reactivated on the Nova 200 in the future. See a full list of training and educational resources for this instrument below.

SEM Applications Ultra-High-Resolution Imaging (Immersion Mode aka UHR Mode) High-Resolution Imaging (Field-Free Mode aka Normal Mode) Secondary Electron (SE) imaging with an Everhart-Thornley Detector (ETD) & Through-the-Lens Detector (TLD) Backscattered Electron (BSE) imaging with a TLD Tungsten deposition via Gas Injection System (GIS) Automated imaging with RunScript program & AutoScript language EDS Applications Spectrum acquisition for qualitative and quantitative compositional analysis Linescan acquisition for 1D spatial compositional analysis Map acquisition for 2D spatial compositional analysis Resources Equipment Status LabRunr Equipment Status (Select Nova 200 NanoLab from the dropdown menu) SOPs & Manuals & SDS KNI Microscopy Policies Nova200 and EDS SOP, Manuals, SDS Nova NanoLab Operation Manual Bruker Quantax EDS Operation Manual Gas Injection Systems – Deposition of Tungsten (Technical Note) Gas Injection Systems – Delineation Etch for SiO2 (Technical Note) Gas Injection Systems – Selective Carbon Etching (Technical Note) Scripting – AutoScript Language Manual (year 2000 Technical Note: most complete) Scripting – RunScript Manual Video Tutorials Getting Started | Basic SEM Alignment Astigmatism Correction (Details | On Right-Angle Features | Stigmator Alignment) Adjusting TLD Voltage to Capture SE vs. BSE Signal Bruker EDS ESPRIT 2 Software (Overview | Basic Spectrum Collection and ID | Spectrum Acquisiton | AutoID Verification | Object Mode (Multi-Point Analysis) | Line Profile Analysis) Graphical Handouts SEM & EDS/WDS Concepts SEM Alignments Guide to Optimizing SEM Imaging Presentations SEM Essentials: Capabilities and Limitations of Scanning Electron Microscopy; and SEM Setup, Parameters and Theory for Successful Operations and Measurements Download .pptx Slides Scanning Electron Microscopy: Principles, Techniques & Applications .pptx Slides | YouTube Lecture Gallium Focused Ion Beam Microscopy: Principles, Techniques & Applications .pptx Slides | YouTube Lecture Simulation Software CASINO Electron Beam Simulation Software – simulate e-beam/specimen interactions (very useful for EDS & WDS) The Stopping & Range of Ions in Matter (SRIM) – simulate i-beam/specimen interactions Calibrate Measurements with NIST Standard The KNI has a NIST-traceable standard against which SEM measurements can be compared. See Slides 54-55 of the SEM Presentation for details. Ask staff for help finding and using the standard in the lab. Sample Preparation Use the Carbon Evaporator to make non-conductive samples conductive by applying 2-10 nm of evaporated carbon. Use the O2/Ar Plasma Cleaner to remove hydrocarbons from the sample surface to avoid creating dark contamination spots on your features while imaging them. Stubs for specimen mounting Stubs used for mounting specimens are considered a personal, consumable item in the KNI. There are some stubs at each Microscope which can be used by any KNI microscopy user. You can also buy your own stubs so that you can keep them clean and available to you. There are many stub geometries and configurations. If you chose to buy your own stubs, please show them to the staff microscopist prior to using them: some stubs including stubs with copper clips have large height differences and can only be used safely in specific operating conditions. Buy stubs without copper clips Guide to Choosing KNI SEMs & FIBs Consult this guide for help in choosing the best SEMs and FIBs for your work Specifications Manufacturer Specifications Nova 200 NanoLab Data Sheet (not all parameters apply to our instrument, see below for details specific to the KNI's Nova 200) SEM Specifications Minimum Feature Size Resolved in Immersion Mode: ~5 nm Voltage Range: 0.2 to 30.0 kV Current Range: ~10 pA to 20 nA Apertures: 30 μm, 40 μm, 50 μm, 100 μm Eucentric Height: ~4.8 mm working distance (WD) Stage Range: ±25 mm X & Y travel, 50 mm Z travel, -12 to 58° tilt, 360° rotation ETD Grid Bias Range: -150 to 300 V TLD Bias Range: -100 to 150 V Ultimate Vacuum: 5e-6 mbar



【本文地址】

公司简介

联系我们

今日新闻

    推荐新闻

    专题文章
      CopyRight 2018-2019 实验室设备网 版权所有